5105GYM100-KE 3ph Motor Pre-Wired

GYM100 Motor

5103GYM70- KE 1ph Motor Pre-Wired

GYM100 Motor

5101SD120CKE + V7 STARTER

SD120CKE

SD120CKE sectional door drive with mechanical limits and ability to add external activations and safety features
Impulse up, deadman down
Easily adjustable mechanical limits, safety back up limits and auxiliary limits
Available with manual override at high or low level
Fully pre-wired with 7 metre control cable
Supplied with 8 metres of haul chain and torque plate

Voltage Output Speed: 400V/3Ph/50Hz 24rpm
Output Torque: 120Nm
Output Power: 0.65kW
Rated Current: 2.8 Amps
Duty Cycle: 60%
Ingress Protection: IP54
Starter: V7 ready for additional safety features and activations
Bore: 1" (25.4mm)

 

Unit: Piece (1)

5102SD120CKE + BUILT ON STARTER

SD120CKE

SD120CKE standard sectional door drive with mechanical limits
Impulse up, deadman down
Easily adjustable mechanical limits, safety back up limits and auxiliary limits
Available with manual override at high or low level
Fully pre-wired with 7 metre control cable
Supplied with 8 metres of haul chain and torque plate

Voltage Output Speed: 400V/3Ph/50Hz 24rpm
Output Torque: 120Nm
Output Power: 0.65kW
Rated Current: 2.8 Amps
Duty Cycle: 60%
Ingress Protection: IP54
Starter: Built On
Bore: 1" (25.4mm)

 

Unit: Piece (1)

5103SD70KE + BUILT ON STARTER

operators motors

SD70KE standard sectional door drive with mechanical limits
Impulse up, deadman down
Easily adjustable mechanical limits, safety back up limits and auxiliary limits
Available with manual override at low level only
Fully pre-wired with 7 metre control cable
Supplied with 8 metres of haul chain and torque plate

Voltage Output Speed: 220V/1Ph/50Hz 24rpm
Output Torque: 70Nm
Output Power: 0.37kW
Rated Current: 6.0 Amps
Duty Cycle: 25%
Ingress Protection: IP54
Starter: Built On
Bore: 1" (25.4mm)

 

Unit: Piece (1)

5108SD70KE + V8 STARTER

operators motors

SD70KE sectional door drive with mechanical limits and ability to add external activations and safety features
Impulse up, deadman down
Easily adjustable mechanical limits, safety back up limits and auxiliary limits
Available with manual override at low level
Fully pre-wired with 7 metre control cable
Supplied with 8 metres of haul chain and torque plate

Voltage Output Speed: 220V/1Ph/50Hz 24rpm
Output Torque: 70Nm
Output Power: 0.37kW
Rated Current: 6.0 Amps
Duty Cycle: 25%
Ingress Protection: IP54
Starter: V8 ready for additional safety features and activations
Bore: 1" (25.4mm)

 

Unit: Piece (1)


All sections in Operators : CHAIN HOSTS , HAND CHAIN & ROPE , CHAIN KEEPS , PNEUMATIC SAFETY , ELECTRIC OPERATORS , ELECTRIC SAFETY OPERATION SAFETY EQUIPMENT .