Mirflex Eco

IMG 1302

Single phase 220V with frequency converter
Indoor use
Maximum sizes 3300 x 3500
Light to moderate air pressure

CURTAIN
Canvas: Base technical fabric of high tenacity polyester impregnated with tinted PVC
Weight: 950 g/m2
Operating temperature -30 to +70 º
Finish: shiny finish on both sides
Reaction to fire: Self-extinguishing M2
Colour: See range
Cross bars for wind resistance
In the standard configuration

Wind resistance:
Standard: Class 0 (no air pressure). For higher classes, tech department must see if
it’s possible.
Intermediate bars: pultruded fibre glass and polyester tubes.
Depending on configuration, 30 x 7.6 composite flat inserts.
Socle: 30 x 15 x 1.5 galvanised steel tube. With flexible elements on side ends
Bottom bag to adjust to the floor

Material: Polyester reinforced fabric impregnated with PVC
Opening system with a Velcro ® strap to access the contact bar and a radio band transmitter

Vision windows (optional):
In PVC crystal clear quality
All welds made on canvas, including connections with the windows are made by radio frequency welding

STRUCTURE

General
Guide-legs and reinforcements in aluminium
Standard colours are Pure White RAL 9010, Grey RAL 9007 and anodised Matte Aluminium Silver
It can optionally be delivered with paint finish in RAL colour of choice

Legs - Guides
Extruded aluminium guide with interior reinforcements specifically designed for this kind of door
Backside squared profile bar with central duct for the guide
Base in stainless steel with holes for floor screwing
Guides in black polyetilene

Head:
Axis formed by:
Aluminium drums of 110 mm diameter
Reinforcement radiuses and central hollow axis knot with keyway

Interior: solid galvanized steel profile of 25.4 mm
Supports: galvanised and painted steel profiles with side handles for the self-adjusting ball bearings that support the shaft
Shaft cover: steel sheet 1.5 mm thick white lacquered or RAL 9006
Fixation:
Head: On a light structure to maintain verticality
Feet: Anchored to ground and one or two intermediate depending on height and air pressure.

MOTOR

Moto reducer
Placed on a side of the head
Irreversible motor reducer for heavy duty with mechanical position switches integrated
Solid shaft with elastic output coupling
Internal parachute
Hollow axis with keyway to connect to door’s shaft axis
Electric brake for accurate positioning and locking of the curtain
Electric brake manual release by a pulling cord
Manual opening system by hand crank (On doors higher than 3000 chain used instead)

Voltage (V) Frequency (Hz): 3 x 230 / 400V. 50 Hz
Power: 0.5 hp
Protection: IP 54
Optional features:
Front motor with chain transmission
Motor cover painted steel sheet in the same colour as the shaft cover

CONTROL PANEL. RSPV Eco

Controls on outer lid: open and stop buttons & tension isolator
Programmable relay with status indicator display and mini buttons that reports about: position, type of failure and counter of operations
Push buttons to open and close by deadman contact and basic programming
Frequency converter: adjustable speed when opening and closing. Deceleration in the last stretch before full opening. Motor protection by over-consumption and lack of phase
PVC box with input and output gland

Protection: IP 65
Voltages: Power supply: 220V single phase
Operation at 24V
Wiring from control panel box to motor protected with a PVC duct

Electrical data
Voltage (V) Frequency (Hz): 2x 230V, 50 Hz.
Power: 0.8 Kw
Protection: IP 54
Electrical wiring to the box must be performed by an electrician and should be a protected installation in accordance with regulations and standards

OTHER FEATURES:
Speeds:
Open: Up to 1 m / s
Slowdown in opening up: 0.6 m / s
Closing: 0.6 m / s

SECURITY SYSTEMS (In accordance with RD 1435/92)
-Pedestrian security: Photocell with reflector placed on structure’s frame
-Bottom of the curtain (leading edge). Painted with diagonal safety stripes Yellow / Black
-Anti-crushing: bottom safety bar by radio band
-Signal flashing lights: Exterior and Interior

Our doors are manufactured according to the UNE-EN 12453:2001 and comply with: harmonisation directives 89/392/EEC, 91/368/EEC and 93/44/EEC, and with the Royal Decree 1435/92 and modification 56/95

They are tested and certified by a notified body in accordance with EN 13241-1

Special Requirements on request